Jan 21, 2025 | BCP
MAINTENANCE :
When switchgear malfunctions, the consequences are often catastrophic. Damage to the switchgear itself can be extremely expensive, but that pales in comparison to corollary damage and the potential hazards to people. Thus, implementing an effective switchgear testing, inspection, and maintenance program is essential. Even switchgear labeled “maintenance free” requires periodic testing and maintenance.
RETROFIT :
Retrofitting refers to the process of updating older equipment with new technology. In the world of industrial electrical equipment, retrofits are regularly used to add functionality to many types of electrical equipment, including circuit breakers, contactors and switchgear.
Why Retrofitting?
Retrofitting of switchgear is a cost effective approach in extending life span of the existing switchgear while incorporating the latest technology into the system. In most instances retrofitting of the breakers can be carried out with little modifications to the existing breaker compartments. The replacement circuit breaker can enhance the life of the switchgear as the original circuit breakers are technically obsolete, too costly to maintain on account of no availability of original spares, unable to interrupt or withstand the ever increasing fault current, or beyond repair due to mechanical wear and tear.
Benefits of Retrofit:
- Increased operating reliability and safety
- Enhanced short circuit ratings available
- Reduced maintenance and environmental impact
- Elimination of hazardous materials such as asbestos
- Service life can be extended
Download Brochure
Dec 24, 2024 | Eaton
Non-Segregated Phase Busduct
– 600 V through 38 kV
– 1200 A through 5000 A
– Copper bus bar
– 130 degree Class B epoxy insulation
– Silver-plated contact surfaces
– Up to 63 kA short circuit withstand ratings 170 kA peak
– Aluminum, steel and stainlesssteel enclosures
– Indoor, outdoor and dust-tight construction
– Accordance with ANSI/IEEE standard C37.23
Download Brochure
Dec 24, 2024 | Eaton
– ANSI / NEMA / EEMAC / UL / CSA Stds
– Type test of seismic withstand capability
– Protects and monitors low voltage electrical distribution systems
– Leader in product innovations
– Patented designs up to 600V, 10000A continous current
– Major customers include Heavy Industrial, Commercial Users with critical processes & Critical Power / UPS OEMs
– Highest interrupting ratings up to 200kAIC
– Short time 30 cycle withstand ratings up to100kA
– Four ACB in one cell cubicle
– Arc resistance type 2B as optional
Download Brochure
Dec 24, 2024 | Eaton
– ANSI / NEMA / EEMAC / UL / CSA Stds
– Type test of seismic withstand capability
– Protects and monitors Low Voltage Electrical Distribution Systems
– Leader in product innovations
– Major customers include Heavy Industrial, Commercial Users with critical processes, & Critical Power / UPS OEMs
– Highest interrupting ratings up to 200kAIC
– Compact dimension:
20”W x 90”H x 16” or 21”D (Front Type)
20”W 90”H 21”D (B k t B k T )20”W x 90”H x 21”D (Back to Back Type)
– Intelegence system as optional
– Arc resistance type 2B as optional
– Enclosures: Indoor, Outdoor Aisle-less, Outdoor Sheltered Aisle, Outdoor Common Aisle
Download Brochure
Dec 24, 2024 | Eaton
Based on the design concept of full insulation and fully sealed, all primary parts within RVAC RMU are fully sealed inside the stainless-steel main enclosure, protect to against condensation and external contaminated environment; the protection degree of the main tank body is up to IP68, equipped with Cooper’s waterproofing touchable cable bond, which can provide effective protection against accidental flood in rainy climate.
– Rated Voltage upto 24kv
– Rated current up to 630A
– Rated interrupting current up to 20kA/3s
– Modular cubicle type
– Capacitive voltage detection system for verification of safe isolation from supply
– Feeder earthing by means of make-proof earthing switch
– Low power loss, low maintenance spending, ensuring more reasonable cost investment
– In normal working conditions, gas leakage rate of lower than 1% ensures more than 30 years life-cycle
– Indoor or Outdoor
Download Brochure