Jan 21, 2025 | BCP
BCP Cable Ladder Tray Systems are designed to meet most requirements of cable and electrical wire installations and comply to local and international standards of fabrication and finishing. Cable Ladder Systems are economical wire and cable management systems designed to support and protect electrical wires and cables.
Cable Ladder in a wide variety of indoor and outdoor applications. Cable Ladder Systems can provide significant advantages in cable filling over other wiring methods. This can provide savings in the size or number of raceways required, thereby, reducing both material and labor costs.
Cable Ladder Systems can supply meet with custom request.
Download Brochure
Jan 21, 2025 | BCP
Non-Segregated Phase Busduct
– 600 V through 38 kV
– 1200 A through 8000A
– Copper or Aluminum, busbar
– 130 degree, Heatsrink Insulation
– Silver or Tinned plated contact surfaces
– Up to 63 kA short circuit withstand ratings 170 kA peak
– Aluminum, steel plate with coating paint and stainless steel enclosure
– Indoor, outdoor and dust-tight construction
– Accordance with IEC 62271-100 & IEEE C37.23
Download Brochure
Jan 21, 2025 | BCP
The CP-F1 series are increasingly adopted in MV installations, owing their superior interrupting features and to their capability to withstand the short circuit currents which occur mainly as consequences of faults in distribution networks.
- Rated Voltage up to 24kV
- Rated Frequency 50/60Hz
- Rated Current 630A
- Rated Short Circuit up to 20kA at 3s
- Full segregation between the busbar compartment and the cable compartment
- Easy Maintenance because more space for cable installation.
- Free Maintenance because use Air LBS not SF6 LBS
- IP 4X
- Cable entry from Bottom or Top
- Indoor or Outdoor
Download Brochure
Jan 21, 2025 | BCP
MAINTENANCE :
When switchgear malfunctions, the consequences are often catastrophic. Damage to the switchgear itself can be extremely expensive, but that pales in comparison to corollary damage and the potential hazards to people. Thus, implementing an effective switchgear testing, inspection, and maintenance program is essential. Even switchgear labeled “maintenance free” requires periodic testing and maintenance.
RETROFIT :
Retrofitting refers to the process of updating older equipment with new technology. In the world of industrial electrical equipment, retrofits are regularly used to add functionality to many types of electrical equipment, including circuit breakers, contactors and switchgear.
Why Retrofitting?
Retrofitting of switchgear is a cost effective approach in extending life span of the existing switchgear while incorporating the latest technology into the system. In most instances retrofitting of the breakers can be carried out with little modifications to the existing breaker compartments. The replacement circuit breaker can enhance the life of the switchgear as the original circuit breakers are technically obsolete, too costly to maintain on account of no availability of original spares, unable to interrupt or withstand the ever increasing fault current, or beyond repair due to mechanical wear and tear.
Benefits of Retrofit:
- Increased operating reliability and safety
- Enhanced short circuit ratings available
- Reduced maintenance and environmental impact
- Elimination of hazardous materials such as asbestos
- Service life can be extended
Download Brochure
Dec 20, 2024 | BCP
We help you create a building to suit the size you need, with the steel structure as the main frame and the metal wall with interlocking system. This model is much in the interest of companies such as oil and gas companies, mining companies on a large scale. Ordinary in place at the project site, because this model is resistant to extreme weather and is equipped with high security systems to hazards.
Download Brochure